Chapter 6 The Extended Audio Matrix. PRELIMINARY Release MSD Software Manual.
To monitor the exact phase relation between any two signals in the Jelly-Fish™
these signals can be routed to the separate ‘Phase Correlation Meter’ which is
destination #53 and #54.
When using a factory preset on a surround sound format using a separate Low
Frequency Energy "LFE" channel (format 5.1 and 7.1) the MSD600M will
include this LFE channel on the PPM-bargraph but since the LFE channel does
not contain any frequency information that can be directional determined it is
NOT included in the Jelly-Fish monitor.
7.3 The Peak Programme Meter (PPM).
The ‘Peak Programme Meter’ is designed for direct measurement of the quasi-
peak level of complex electrical signals ocuring in the transmission of music
and speech, without varying the sensitivity of the device, to achieve optimum
technical utilization of the transmission channel, or the recording medium.
For this purpose a full-wave rectifier is used, and the integration time is chosen
to obtain an amplitude as high as possible, without overloading the
transmission link for a period long enough to give rise to audible non-linear
distortion of the programme. The return time is relatively long in order to avoid
unnecessary viewer fatigue.
The ‘Peak Programme Meter is capable of showing up to 32 input channels
simultaneously. The number of visible channels are configured in the Audio
Matrix. When PPM-bars are enabled or disabled the Audio Vector Scope
window is automatically scaled to fill the remaining part of the screen. See
section 4 for information on how to route audio channels to the PPM bars.
(Destinations #65 to #96.) Please observe that if the Jelly-Fish™ is active the
maximum number of active PPM-bargraphs is 16.
Please refer to section 6.3.1 for information on how to change the appearance
of the PPM bargraphs.
The configuration of the ‘Peak Programme Meter is done from the [Meter]
menu.
Page 24 of 64. PRELIMINARY Release