Page 57 of 108
4. LC2 (MEDLINE
®
CARELINE
®
TECHLINE
®
)
The LC2 column is an update of the LP2 programme. It has an improved
“twisting” stability and end-stop switches as standard.
The column is designed to be used in a vertical position and only for
lifting purposes. It is not possible to use the column in any kind of “pull”
application.
Depending on the application, the LC2 can be operated either as a single column or several columns in a parallel system by choosing a control box
with microprocessor.
It is designed to provide vertical lifting (push only) where simultaneous bending and torsion moments may occur.
Warning!
Do only use the column within specified working limits.
The LP2 lifting column is the ideal choice for duties such as height adjustment on computer workstations, work benches, or a wide selection of other duties.
• There are mounting holes in the end plates.
• The largest profile must be mounted uppermost.
The LP2 range of vertical lifting columns is ideal where vertical positioning of
substantial loads is required.
The design allows the LP2 range to be built in a complete motion control system
simply by adding a suitable LINAK control box and handset.
Advanced design and high quality construction allows the column to be operated
either as single or parallel with up to a maximum of four units and/or with a memory
function.
5. LP2 (DESKLINE
®
MEDLINE
®
CARELINE
®
TECHLINE
®
)
Warning!
Do only use the column within specified working limits.
Warning!
Ensure a safe connection between column and application
Warning!
Side mounting bracket screws: use the correct torque on the side mounting bracket screws.
Warning!
The column can not be used in pull
Warning!
Max. bending: LP22 = 550 Nm
LP25 = 1000 Nm