Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader
Tel 800.624.5625 [email protected]
in door opening solutions
© Copyright, 2011, all rights reserved PN# 500-24010
Page 1 Rev. C, 04/11
SECURITRON MODEL DK-12 DIGITAL KEYPAD
INSTALLATION & OPERATING INSTRUCTIONS
1. SPECIFICATIONS
MECHANICAL ELECTRICAL/ENVIRONMENTAL
Keypad Dimensions:
2” x 2-3/4” x 1/4” (Width x Length x Height
off of stainless steel faceplate)
Stainless Steel Faceplate Dimensions:
2-3/4” x 4-7/16” x 5/32” (Width x Length x
Height)
Back Board Dimensions:
1-29/32” x 2-13/16” x 1-1/16” (Width x
Length x Height off of stainless steel
faceplate)
Power Supply:
12/24VDC @ 100 milliamps maximum
12/24VAC @ 325 milliamps maximum
Relay Contacts:
Maximum 5 amps @ 30 volts
Environmental:
Operating: -10°F [-23°C] to 140°F [60°C]
Storage: -10°F [-23°C] to 150°F [65.6°C]
Humidity: 0% to 95% RH
2. INSTALLATION
SURFACE MOUNT WALL BOX
Separate the wall box cover and base.
Remove rectangular knockout in the center of the base.
Cut out opening in the wall that will be used to route the wires through.
Mount base to wall over wire opening using the #6 sheet metal screws and plastic anchors.
Mount DK-12 to cover with either tamper resistant #6 screws (recommended) or #6
conventional screws. See Section 7 (Programming) before securing DK-12 in place.
Pull wires through wall/center of base and connect to DK-12 wiring terminals (see Section 3
for wiring instructions).
Push the wall box cover onto the base until it snaps into place.
FLUSH MOUNT WALL BOX
Cut out opening in wall to mount box into.
Route wiring through one of the four knockouts in the back of the box.
Push the box into the wall and secure in place using the two swing clamps.
Connect wires to DK-12 wiring terminals (see Section 3 for wiring instructions).
Mount DK-12 to box with either tamper resistant #6 screws (recommended) or #6
conventional screws. See Section 7 (Programming) before securing DK-12 in place.
The DK-12 can be used outdoors with the optional rain cover (Securitron part #WCC) which will
allow the DK-12 to be mounted in outdoor locations not directly exposed to rain or snow. When
used outdoors you must supply a weatherproof, gasketed wall box (available from Securitron
under part #WBB).
3. WIRING
Wiring Terminal Connections
:
1. ‘AC/DC+’ One AC supply lead or positive DC supply lead.
2. ‘AC/DC-’ Other AC supply lead or negative DC supply lead.
3. ‘NC’ Normally closed relay contact.
4. ‘COM’ Common for relay contacts.
5. ‘NO’ Normally open relay contact.
6. ‘SRC’ Supply for REX signal.
7. ‘REX’ REX Signal input.
NOTE: Each terminal is provided with a marking in front of it for
easy reference.
1
2
3
4
5
6
7
DK-12
Back Side
Wiring
Terminals
AC/DC+
AC/DC-
NC
COM
NO
SRC
REX
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1

Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solution

Seite 2 - Page 2 Rev. C, 04/11

PN# 500-24010 Page 2 Rev. C, 04/11 Basic Power and Electric Lock Connections:  Connect supply to ‘AC/DC+’ and ‘AC/DC-’ terminals.  Connect

Seite 3 - Page 3 Rev. C, 04/11

PN# 500-24010 Page 3 Rev. C, 04/11 Double Break Wiring For Free Egress (SPDT):  Connect DC supply to ‘AC/DC+’ and ‘AC/DC-’ terminals.  Con

Seite 4 - Page 4 Rev. C, 04/11

PN# 500-24010 Page 4 Rev. C, 04/11 INDICATOR ACTION MEANING Green Light Continuously On While in normal mode a 30-Second lockout occurred afte

Seite 5

PN# 500-24010 Page 5 Rev. C, 04/11 Setting/Changing Codes:  Enter program code on the keypad.  Press either ‘#’ or ‘’ and the yellow ligh

Seite 6 - Page 6 Rev. C, 04/11

PN# 500-24010 Page 6 Rev. C, 04/11 As delivered the DK-12 echoes key presses by a short flash of the green light. The red light flashes once p

Seite 7 - Page 7 Rev. C, 04/11

PN# 500-24010 Page 7 Rev. C, 04/11 energize automatically after that timer period expires. The default time is 5 seconds but it can be changed

Seite 8 - Page 8 Rev. C, 04/11

PN# 500-24010 Page 8 Rev. C, 04/11 occur if a user code was a subset of the program code. The unit could not be put into programming mode from